Find and compare providers
Find a heat pump installer in Luxembourg
Compare verified heat pump installers in Luxembourg for air-to-water, geothermal and hybrid systems. A standard air-water install sits between €12 000 and €18 000, geothermal between €20 000 and €35 000 including ground loop and drilling. Klimabonus 2026 refunds up to €10 000 on air-water and €12 000 on geothermal, capped at 50 % of the invoice, when the installer is Klima-Agence accredited and the unit uses an inverter compressor. Insist on a heat-loss calculation before sizing, and get the electrical feasibility checked — a heat pump often triggers a main-fuse upgrade.
Describe what you need in natural language. Fynd's AI assistant helps structure the request, clarify the right questions, and contact relevant heat pump installer profiles.
4 matching public profiles are connected to this category on Fynd.
Heat Pump Installers on Fynd
Browse visible heat pump installers profiles before you start a quote request. Provider names, locations, and profile links help you move from research to a concrete shortlist.
Examples of public profiles
4 matching profiles
Trust signals to verify before you shortlist
- Sizing method, heat-loss assessment and experience with your emitter type.
- Commissioning, maintenance, electrical coordination and subsidy/admin readiness.
- References for comparable houses, not only generic heating work.
Directory results
18 profiles loaded for browsing


a + p kieffer OMNITEC


Arctic Cooling Systems Sàrl


CARA LUX - PLOMBIER CHAUFFAGISTE LUXEMBOURG


Celsius Sàrl


Chauffage Artisanal

Chauffage-Sanitaire Percy Rauchs

Climalux S.A.
Heat Pump Installers in your commune
Browse the largest communes across Luxembourg.
- Heat Pump Installers·Luxembourg CityHeat Pump Installers in Luxembourg City
- Heat Pump Installers·Esch-sur-AlzetteHeat Pump Installers in Esch-sur-Alzette
- Heat Pump Installers·DifferdangeHeat Pump Installers in Differdange
- Heat Pump Installers·DudelangeHeat Pump Installers in Dudelange
- Heat Pump Installers·PétangeHeat Pump Installers in Pétange
- Heat Pump Installers·SanemHeat Pump Installers in Sanem
- Heat Pump Installers·HesperangeHeat Pump Installers in Hesperange
- Heat Pump Installers·BettembourgHeat Pump Installers in Bettembourg
- Heat Pump Installers·KäerjengHeat Pump Installers in Käerjeng
- Heat Pump Installers·SchifflangeHeat Pump Installers in Schifflange
Common jobs and project types
Use this list to decide whether you need a specialist heat pump installer, a broader company, or several trades working together.
- Air-to-water heat pump installation
- Geothermal (ground-source) heat pump
- Hybrid gas/heat-pump system
- Underfloor heating upgrade for heat-pump use
- Annual maintenance and refrigerant check
- Klimabonus subsidy filing
How to choose the right provider
Ranking well for a service search depends on proving useful decision support, not just naming the service. These are the checks users should be able to complete before making contact.
Klima-Agence accreditation
Klimabonus is only unlocked by installers on the Klima-Agence register. Confirm the listing and the autorisation d'établissement before any deposit.
A quote promising Klimabonus without the installer's listing number on it is either optimistic or fraudulent. Don't sign.
Heat-loss calculation in writing
An installer who proposes a heat-pump size without a written heat-loss calculation is guessing. A correctly-sized unit runs quieter, lasts longer and qualifies more cleanly for Klimabonus.
Right system type for your building
Air-water suits well-insulated detached and semi-detached houses with outdoor space. Geothermal fits larger plots and high annual heat demand where the drilling payback (12 to 15 years longer than air-water) is justified by stable ground-loop COP. Hybrid gas/heat-pump makes sense for older urban townhouses awaiting insulation upgrades — the gas burner covers the coldest hours.
Noise class and outdoor-unit placement
Ask for the sound-power level (Lw) in dB(A) from the datasheet, not just the perceived sound-pressure number. Premium air-water units sit at Lw 52 to 58 dB(A); anything above 62 dB(A) triggers neighbour complaints in Luxembourg's typical lot spacing. Confirm the unit can run in silent mode overnight without a performance penalty.
A quote that quotes only sound pressure at 10 m distance (intentionally low) without the Lw figure is hiding the number you need for a neighbour complaint.
When to contact a provider
Replacing an old oil or gas boiler
If the boiler is over fifteen years old, heat-pump replacement with Klimabonus usually beats a like-for-like swap on ten-year total cost. Start the Klima-Agence consultation before signing anything.
Deep renovation with new insulation
A heat pump only performs when the building's heat loss is low enough. Order the thermal study first; install the pump last once walls, roof and windows are tight.
New construction with underfloor heating
In a new-build, the underfloor circuit, the heat pump and the photovoltaic array are usually scoped as one bid package. Coordinating all three with the same integrator cuts coordination overhead.
Existing heat pump running inefficiently
If your current unit cycles frequently, runs the electric backup through winter, or the room temperature lags the thermostat, the root cause is almost always undersized buffer, incorrect flow temperature setting, or a failed mixing valve. A qualified technician rebalances for €400 to €900; replacement is rarely the right first move.
What to compare in quotes
- Heat-loss sizing, current heating emitters, insulation level, outdoor-unit placement, noise, access, and electrical capacity.
- Appliance, buffer tank, hydraulics, controls, commissioning, subsidy/admin support, and maintenance contract separated.
- Whether radiators, underfloor heating, boiler removal, drilling, or backup heat are included or excluded.
Luxembourg checks before you hire
Permits depend on the commune
Construction, transformation, facade, roof, demolition, and change-of-use work can require a building permit from the mayor of the commune. Interior work that does not touch structure, facade, or roof is usually lighter, but commune rules still matter.
3% VAT can apply only under conditions
Eligible housing construction or renovation work may use Luxembourg's super-reduced 3% VAT route when the home is used as a main residence and the AED conditions are met.
Check business authorisation
For regular commercial, craft, and many liberal activities in Luxembourg, ask who holds the autorisation d'etablissement and whether the quoted work matches that activity.
Ask for insurance in writing
Before work starts, get civil liability or professional insurance details in writing, especially when the provider enters your home, handles keys, or works on fixed installations.
FAQ
How much does a heat pump cost installed in Luxembourg?
Air-water heat pumps run €12 000 to €18 000 installed. Geothermal sits between €20 000 and €35 000 including drilling. Klimabonus 2026 can refund €10 000 on air-water and €12 000 on geothermal, bringing net cost to roughly €6 000–9 000 and €10 000–23 000 respectively. Condition: the installer must be Klima-Agence registered.
Does a heat pump work in an older, poorly insulated house?
It can, but performance drops sharply below a minimum insulation level. Order a heat-loss calculation first. If the figure exceeds roughly 100 W/m², insulate the roof and upgrade the windows before installing — otherwise the compressor will run on electric backup at cost parity with oil.
Will I need to upgrade my electrical panel?
Often yes. A heat pump adds 2 to 4 kW of continuous draw and typically needs a dedicated circuit. If your main fuse is 40 A or less, expect a €1 200 to €2 500 panel upgrade plus Creos paperwork. Ask the heat-pump installer to coordinate with a licensed electrician on the same schedule.
Will the outdoor unit bother my neighbours?
Modern inverter units run at 45–55 dB(A) at one metre — roughly a whisper at night. Luxembourg municipal noise rules typically cap 35 dB(A) at the property line between 22:00 and 06:00. Place the unit at least two metres from the boundary, use rubber mounts and schedule the compressor to down-modulate overnight.
Useful cost signals
Air-to-water heat pump, installed
12.000 € - 18.000 €Covers 8–12 kW inverter unit, buffer tank, hydronic connection to existing circuit, commissioning. Radiator or floor-heating adaptations quoted separately. Excludes VAT (17 %, 3 % reduced rate often applies).
Geothermal heat pump, installed (incl. drilling)
20.000 € - 35.000 €Covers vertical borehole(s) to 100–150 m, ground-loop filling, heat pump and commissioning. Variance driven by soil conditions and whether drilling permits require a hydrogeological study. Excludes VAT.
Annual maintenance visit
180 € - 320 €Standard check: refrigerant pressure, filter, expansion vessel, electrical contacts. Required by most manufacturer warranties and by Klimabonus eligibility. Excludes VAT.